APC Smart-UPS C 2000VA 2U Rack mountable 230V (SMC2000I-2U)

    Liên hệ

    SMC2000I-2U

    Thông tin nhanh về sản phẩm

    Smart-UPS
    SMC2000I-2U
    APC Smart-UPS C 2000VA 2U Rack mountable 230V
    Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.


    Thay ắc quy (Replacement Battery)
    APC Replacement battery cartride #133 (APCRBC133)
    RBC #133 x 1
    = 24VDC, ([12V-7.2AH x 2] x 2) hoặc ([12V-9AH x 2] x 2) = 4pcs
    [LONG 12V-7.2AH, WP7.2-12 HOẶC 12V-9AH, WP1236W] x 4
    Thông số kỹ thuật

    Output

    • Output power capacity
      1.3 KWatts / 2.0 kVA
    • Max Configurable Power (Watts)
      1.3 KWatts / 2.0 kVA
    • Nominal Output Voltage
      230V
    • Output Voltage Distortion
      Less than 5%
    • Output Frequency (sync to mains)
      50 Hz
    • Topology
      Line Interactive
    • Waveform type
      Sine wave
    • Output Connections
      (6) IEC 320 C13 (Battery Backup)
    • Transfer Time
      8ms typical : 10 ms maximum

    Input

    • Nominal Input Voltage
      230V
    • Input frequency
      50/60 Hz +/- 3 Hz (auto sensing)
    • Input Connections
      IEC-320 C20
    • Input voltage range for main operations
      180 - 287V
    • Number of Power Cords
      1

    Batteries & Runtime

    • Battery type
      Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
    • Typical recharge time
      3hour(s)
    • Replacement Battery
      APC RBC #133
    • Expected Battery Life (years)
      3 - 5
    • RBC Quantity
      1
    • Battery Volt-Amp-Hour Capacity
      432
    • Runtime

    Communications & Management

    • Interface Port(s)
      USB
    • Control panel
      Multi-function LCD status and control console
    • Audible Alarm
      Alarm when on battery : distinctive low battery alarm : configurable delays
    • Emergency Power Off (EPO)
      --

    Surge Protection and Filtering

    • Surge energy rating
      300Joules
    • Filtering
      Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449

    Physical

    • Maximum Height
      89mm , 8.9cm
    • Maximum Width
      480mm , 48.0cm
    • Maximum Depth
      470mm , 47.0cm
    • Rack Height
      2U
    • Net Weight
      26.2kg
    • Shipping weight
      30.16kg
    • Shipping Height
      250mm , 25.0cm
    • Shipping Width
      590mm , 59.0cm
    • Shipping Depth
      600mm , 60.0cm
    • Color
      Black
    • Units per Pallet
      16.0

    Environmental

    • Operating Environment
      0 - 40 °C
    • Operating Relative Humidity
      0 - 95 %
    • Operating Elevation
      0-3000meters
    • Storage Temperature
      -15 - 45 °C
    • Storage Relative Humidity
      0 - 95 %
    • Storage Elevation
      0-15000meters
    • Audible noise at 1 meter from surface of unit
      42.0dBA
    • Online thermal dissipation
      81.0BTU/hr

    Conformance

    • Approvals
      C-tick, CE, EAC, GOST, GS Mark, IRAM, SABS, VDE
    • Equipment protection policy
      Lifetime : $150000
    • Standard warranty
      2 years repair or replace

    Sustainable Offer Status

    • RoHS
      Compliant
    • REACH
      REACH: Contains No SVHCs
    Hỗ trợ tài liệu
    Sản phẩm cùng nhóm
    Bình luận Facebook
    SẢN PHẨM ĐÃ XEM